Features:
* Brand new and high quality
* Made of high quality materials, sturdy and
* MR9270S+HART multi-function signal generator adopts high-speed AR M CPU, with strong performance, stable operation and friendly interface.
* MR9270S+HART multi-function signal generator adopts nylon shell, silicone buttons with backlight, and high transmittance tempered mirror.
* MR9270S+HART multi-function signal generator can measure and output signals (current, voltage, MV, frequency, resistance, thermocouple, thermal resistance, PT100) at the same time
* MR9270S+HART multifunctional signal generator, with HART protocol, MODBUS protocol, paperless recorder, signal conversion, real-time curve, programming output and other functions.
* HART communication protocol.
* Measure and output signals simultaneously.
* Programmable output of current and voltage signals, with two output modes.
* The first mode: set the starting point, end point, and number of cycles to start working.
* The second mode: Advanced mode, all signal changes are set by parameters.
* Default value: 9 sets of commonly used signal values can be preset for quick output.
* Convert input signal to output signal, for example: convert input frequency signal to current signal, convert input range 0-1000Hz to 4-20mA.
* Real-time curve: The changing for trend of the input and output signals can be displayed through the curve, the acquisition time of the curve can be set, and the maximum and minimum values within a certain time range can be automatically displayed.
* Conversion of engineering quantity display: display the signal as signal value or engineering quantity, and the signal value corresponds linearly to the engineering quantity. For example, a 4-20mA signal corresponds to 0-100, that is, 4mA corresponds to 0, 12mA corresponds to 50, and 20mA corresponds to 100. This range can be modified through parameters.
* Modbus RTU remote control: It can communicate with configuration software or PLC through RS485 to realize online setting of instrument output signals and monitoring of instrument input signals.
* Modbus RTU master station: performs communication testing, parameter setting, parameter copying, online monitoring and other operations for slave devices with RS485 MODBUS interface.
* Modbus Rtu custom slave station: can simulate various variables of modbus devices for configuration software or PLC debugging
* Instrument tool set: as a function extension of the instrument, such as a simple paperless recorder, PID controller, etc. Please pay attention to the product website for details. This manual does not provide instructions.
* USB firmware upgrade: Upgrade new firmware to expand new functions.
* USB to RS485: The instrument can be used as a USB to RS485 virtual serial port. Operating s below WIN10 need to install the driver.
Specification:
Type: MR9270S+, MR9270S+ Hart (optional)
Built-in 3.6V 2500mA polymer lithium battery; standby time is about 20 hours; usage time depends on usage (20mA continuous output can reach 8-10 hours)
Working environment: 0℃-50℃.
Internal reverse and overcurrent protection; Protection voltage: 30V
Size: 97mm*76mm*33mm
Package Included:
1 x signal generator
1 x Kit (Black)
1 x manual
1 x RS485 adapter
1 x USB cable
1 x charger (random black and white color)
1 x 10A/4mm test fixture (yellow)
1 x 10A/4mm test fixture (blue)
1 x 10A/4mm test fixture (red)
1 x 10A/4mm test fixture (black)
Note:
1.The real color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.
2.Please allow slight manual measurement deviation for the data.