Features:
Dual power supply (two power supplies cannot be powered at the same time): Power supply 1, DC 6.525V; Power supply 2, DC 5V
Working current: (Normal Mode) standby current 41mA, working current 83mA;
(EnergySaving mode) Standby current 7mA, working current 44mA.
There are three input control port: forward control(FWD), reverse control(REV), and stop control(STOP).
Two input trigger modes, LowPulse trigger mode, LowLevel trigger mode
Delay time: 0.1999.9 seconds, 19999 seconds, 19999 minutes.
Cycle times: no cycle, 299 cycles, always cycle.
Three indicators: forward indicator(F LED), reverse indicator(R LED), stop indicator(S LED).
Relay load current, recommended less than 5A.
This is a multifunction DCAC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings.
Port:
DC 5.5MM female : Power supply 1, DC 5V power supply.
VIN: Power 2 positive, DC 6.525V power supply
GND: Power supply 2 negative
FWD: Forward input control (partial FunctionMode is invalid)
REV: Reverse input control (partial FunctionMode is invalid)
STOP : Stop input control (partial FunctionMode is invalid)
M+: Motor positive
M: Motor negative
P+: Positive terminal for motor power supply
P: negative terminal for motor power supply
Specification:
Power supply: DC 6.525V, DC 5V
Working current: 83mA
Standby current: 41mA
Relay load current: <5A
Delay time: 0.1999.9 seconds, 19999 seconds, 19999 minutes
Size: 8*5cm3.2*2in
Weight: Approx. 51g1.8oz
Trigger mode:
1 low pulse trigger (falling edge trigger)
2 low level trigger (rising edge trigger)
Timer:
T1: Forward timer
T2: Reverse timer
T3: Stop timer
Time unit : 0.1 second, 1 second, 1 minute
Relay action:
Motor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing.
Motor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing..
Motor stop : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.
Factory settings:
Press the "++" and "" buttons simultaneously for 5 seconds.
Energysaving mode:
Press and hold the "OK" button for 5 seconds to enter
the "Energysaving mode". Press and hold the "OK" button again for 5
seconds to exit the "Energysaving mode". Energy saving mode just turns
off the digital tube and LED indicator, and other functions are normal.
Function mode:
F01
After poweron, the motor is forward T1 time; then the
motor stops T3 time; then the motor reverse T2 time; so it is repeated
Nx times. When the STOP port is triggered, the motor stops working
immediately. (FWD, REV port is invalid)
F02
This function is a F01 variant. F01 is run directly
after poweron, but F02 needs to trigger FWD or REV port to run.
F11(Trigger reversible 1)
Trigger the FWD port, the motor is forward T1 time, and
automatically stops (in order to protect the motor, during the delay
period, trigger the REV port to stop T3 time and then reverse T2 time,
trigger FWD port to retime T1).
Trigger the REV port, the motor is reverse T2 time, and
automatically stops (in order to protect the motor, during the delay
period, the FWD port is triggered to stop the T3 time and then the T1
time is forward, and the REV port is retimed T2).
When the STOP port is triggered, the motor stops
immediately, regardless of whether the motor is forward or reverse.
F12(Trigger reversible 2)
Trigger the FWD port, the motor is forward T1 time and
stops automatically (during the delay period, except for triggering STOP
port, the other ports are invalid).
Trigger the REV port, the motor is reverses T2 time, and
automatically stops (during the delay period, except for triggering
STOP port, the other ports are invalid).
When the STOP port is trigger, the motor stops
immediately, regardless of whether the motor is forward or reverse.
F21
When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.
When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops.
In this mode, the FWD and REV ports cannot be connected
low level at the same time, and the STOP port is invalid.
F22
When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.
When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops.
In this mode, the FWD and REV ports cannot be connected
low level at the same time, triggering the STOP port, the motor stops
immediately.
Parameter setting:
There are three menus: Work Menu, Function Menu, Parameter Menu.
Note: When entering the "Function Menu" or "Parameter
Menu", the module still works normally (countdown and the trigger is
running normally). The set parameters are valid only after being powered
on again.
1 Power on to enter the running state (Work Menu).
If the current function is F01, then the motor direct
run and the digital tube displays the countdown. F01 is displayed after
the operation is completed.
If the current function is other functions, such as
F11. Then the digital tube displays F11. After the trigger, the
digital tube displays the countdown. After the operation is completed,
F11 is displayed.
<Description: The forward countdown F LED indicator flashes, the reverse
countdown R LED indicator flashes, and the S LED indicator flashes when
stopped.|
Function
mode
Digital
tube
display
Setting
method
Function
01
F101
Short
press
the
"SET"
button
to
enter
the
setting
state,then
use
the
"++"button
and
the
""button
to
select
the
corresponding
submenu
setting,short
press
the"OK"
button
to
return
to
the
previous
menu
Function
02
F102
Function
011
F111
Function
012
F112
Function
21
F121
Function
22
F122
2 In the running state(Work Menu), short press the SET button to enter the "Function Menu" (Above table).
Digital
tube
bit
1(parameters)
bit2
bit34
parameter
definition
default
parameter
1
0099
Time
T1:single
digit
and
tens
digit
04
2
0099
Time
TI:hundreds
digit
and
thousands
digit
00
3
0099
Time
T2:single
digit
and
tens
digit
02
4
0099
Time
T2:hundreds
digital
and
thousands
digita
00
5
0099
Time
T3:single
digit
and
tens
digit
01
6
0099
Time
T3:hundreds
digit
and
thousands
digit
00
7
0103
01:0.1seconds
02:second
03:minute
time
unit
02
8
099
number
of
cycles
1
9
0102
01
low
pulse
trigger
02
low
level
trigger
trigger
mode
01
Package list:
1 x Motor Controller board
Dual power supply (two power supplies cannot be powered at the same time): Power supply 1, DC 6.525V; Power supply 2, DC 5V
Working current: (Normal Mode) standby current 41mA, working current 83mA; (EnergySaving mode) Standby current 7mA, working current 44mA.
There are three input control port: forward control(FWD), reverse control(REV), and stop control(STOP).
Two input trigger modes, LowPulse trigger mode, LowLevel trigger mode
Delay time: 0.1999.9 seconds, 19999 seconds, 19999 minutes.